Lynx PowerBank Specifications

 

Lynx PowerBank Specifications 

 

 

 

 

 

 

 

Projects 

Specification 

Remark 

 

 

 

 

Individual Prismatic Cell Specification 

 

 

 

 

 

 

 

Battery Types and Materials 

 LiFePO4 

Lithium Iron Phosphate 

 

Rated Voltage/Capacity 

3.2V/202Ah 

 

 

Single Battery Voltage Range 

2.5V~3.65V 

 

 

Single Battery Weight 

4.2Kg 

 

 

Battery Internal Resistance 

≤ 0.6mΩ 

 

 

Battery Cell Size 

6.9"x2.1"x7.9"  

(LxWxH) 

 

 

 

 

Power Bank Specifications 

 

 

 

 

 

 

 

Rated Voltage 

51.2V 

 

 

Rated Capacity 

202Ah 

 

 

Battery Pack Voltage Range 

40.0V~58.4V 

 

 

Total Energy 

10.34kWh 

 

 

Combination In Parallel 

1P16S 

Up to 16 - 10Kw Units 

 

Insulation Resistance Test Value  

≥20MΩ 

 

 

Operating Temperature 

 

 

 

         Charging  

0 ~ 45°C 

 

 

         Discharging 

-30 ~ 60°C 

 

 

Standard Charging Current  

40A 

 

 

Standard Discharge Current 

≤100A 

 

 

Gross Weight 

95KG 

 

 

PowerBank Size 

23.6"x11.9"x21.7"  

(LxWxH) 

 

Installation Method  

Floor mounted 

 

 

Communication  

RS485 

One supported 

 

Lynx PowerBamk BMS Specifications 

 

 

 

 

 

 

 

Item 

Specification 

Time delay 

Remark 

    

 

 

 

Cell Overvoltage Warning  

3.6V  

Just a warning 

 

Cell Overvoltage Cutoff  

3.65V  

5S  

Cut output 

Cell Overvoltage Recover  

3.6V 

Maximum voltage is less than that 

Cell Undervoltage Warning 

2.80V 

Just a warning 

 

Cell Undervoltage Alarm 

2.5V  

5S 

Cut output 

Cell Undervoltage Recovery 

2.6V 

 

 

Charge High Temperature Warning 

50 

Just a warning 

 

Charge High Temperature Alarm 

55  

Cut output 

 

Charge High Temperature Recovery 

50 

Less than that 

Cut output 

Discharge High Temperature Warning  

55  

Just a warning 

 

Discharge Temperature Alarm 

60 

Cut output 

 

Discharge Temperature Recovery 

55  

less than that  

Cut output 

Charge Low Temperature Warning 

5 

Just a warning 

 

Charge Low Temperature Alarm  

0 

Cut output 

 

Charge Low Temperature Recovery 

5 

 

 

Discharge Low Temperature Warning 

-10 

Just a warning 

 

Discharge Low Temperature Alarm 

-15 

Cut output 

 

Discharge Low Temperature recovery 

 -10 

 

 

Charging Over Flow Alarm 

150A 

3S 

Cut output 

Charging Recharge Flow Recovery 

30S 

 

 

Discharge Over Flow Alarm  

180A 

3S 

Cut output 

Discharge Over Flow Recovery 

30S 

 

 